FIRE ALARM SYSTEMS

Detect fire before it happens


Unsplashed background img 1

Do not lose valuable data and properties or even lives just in a twinkle of an eye. Fire alarm systems are important accessories to every building and household.

The Fire alarm system can be Conventional or Addressable depending on the building architecture and end-user preferences. In places where the specific zone of the alarm needs to be identified, the addressable system is used.

 

The two types of Fire Alarm system

 

Conventional fire alarm systems

Most of the conventional fire alarm panels are certified to EN54-2/4 standard and providing 2 to 8 fixed zones expandable to 16 zones. Up to 20 ( 32 SensoMAG Series) fire detectors can be connected to every fire zone. Unlimited number of call points can be connected to each of the fire zones.  The panel is easy for installation and maintenance and provides user-friendly daily operation.

Functional features

  • 4 fully monitored fire zones with up to 32 fire alarm detectors and unlimited number of call points
  • 2 monitored siren outputs – 300mA
  • 1 “fire” and 1 “fault” relay output
  • Active EOL allowing continuous monitoring of inputs
  • “One man” zone testing
  • Multilanguage support
  • LED indication
  • Security key
  • Plastic box

 

Addressable fire alarm system

For addressable fire alarm panel, we have the IRIS and SIMPO. The IRIS addressable fire alarm panel has 1 to 4 loops and maximum coverage of 96 zones while the SIMPO has up to 2 loops panel with coverage of 48 zones. Up to 250 devices can be connected to every system loop.

With the IRIS,  information for the system status is visualized on sensitive graphic display and LED indication for zones and troubles but with SIMPO, system status is visualized via LCD display and LED indication. With special 2 steps of alarm level working algorithm the false alarms are effectively minimized.

Functional features

  • Loops: 1 to 4 (both TTE and SS loops can be mounted in random configuration)
  • Devices per loop: 250 (TTE loop)/ 198 (SS loop)
  • Standard: EN54 – 2/4 certified
  • Programmable inputs/outputs: up to 250
  • Zones: 96
  • Outputs (monitored, relay): 4
  • Outputs (non-monitored, programmable, relay): 4, 15A@24VDC
  • Memory LOG: 10 000 events
  • Panels in Ethernet network (built in TCP/IP): Up to 32
  • Panels in RS485 redundant network (optional module): Up to 32
  • Thermal printer: Optional
  • Display: 320/240 touch screen
  • Multi language support: Yes (English, Italian, Portuguese, Russian, Turkish, Polish, Croatian, Dutch, Latvian, French, Bulgarian currently available)
  • Programming: ProsTE software
  • Auto addressing function


Detector

Control Panel

Control Panel

Detector